RDS生产用涂布计量棒选型表【选型】

RDS生产用涂布计量棒实际的转移率会受涂料流变性,基材以及其他变量的影响。这个表格的目的是为试验提供一个好的起点。实际上,转移率也受棒型的影响,因为棒的轮廓对涂料的流动也会有明显的影响。同时也请注意,干膜重量的计算前提是假设涂料的密度为1.0 g/cm³。

钢线直径湿膜厚度干膜重量可选型号
(或等效)固含量%65绕线式压铸式
No.InchmmMilsMicronsGSM#/3000
30.0030.080.307.64.953.04
40.0040.100.4010.26.604.06
50.0050.130.5012.78.265.07
60.0060.150.6015.29.916.09
70.0070.180.7017.811.567.10
80.0080.200.8020.313.218.12
90.0090.230.9022.914.869.13
100.0100.251.0025.416.5110.15
110.0110.281.1027.918.1611.16
120.0120.301.2030.519.8112.18
130.0130.331.3033.021.4613.19
140.0140.361.4035.623.1114.21
150.0150.381.5038.124.7715.22
160.0160.411.6040.626.4216.23
170.0170.431.7043.228.0717.25
180.0180.461.8045.729.7218.26
190.0190.481.9048.331.3719.28
200.0200.512.0050.833.0220.29
210.0210.532.1053.334.6721.31
220.0220.562.2055.936.3222.32
230.0230.582.3058.437.9723.34
240.0240.612.4061.039.6224.35
250.0250.642.5063.541.2825.37
260.0260.662.6066.042.9326.38
270.0270.692.7068.644.5827.40
280.0280.712.8071.146.2328.41
290.0290.742.9073.747.8829.42
300.0300.763.0076.249.5330.44
310.0310.793.1078.751.1831.45
320.0320.813.2081.352.8332.47
330.0330.843.3083.854.4833.48
340.0340.863.4086.456.1334.50
350.0350.893.5088.957.7935.51
360.0360.913.6091.459.4436.53
370.0370.943.7094.061.0937.54
380.0380.973.8096.562.7438.56
390.0390.993.9099.164.3939.57
400.0401.024.00101.666.0440.59
420.0421.074.20106.769.3442.62
440.0441.124.40111.872.6444.64
450.0451.144.50114.374.3045.66
460.0461.174.60116.875.9546.67
480.0481.224.80121.979.2548.70
500.0501.275.00127.082.5550.73
550.0551.405.50139.790.8155.81
600.0601.526.00152.499.0660.88
650.0651.656.50165.1107.3265.95
700.0701.787.00177.8115.5771.03
750.0751.917.50190.5123.8376.10
800.0802.038.00203.2132.0881.17
850.0852.168.50215.9140.3486.25
900.0902.299.00228.6148.5991.32
950.0952.419.50241.3156.8596.39
  • 实际涂布率还受涂料的流变性和其它因素影响。

  • 干膜涂层重量计算假设涂层密度为1.0g/cm³

  • GSM = 每平方米克数

  • #/3000 =每3000平方英尺的榜数

  • % 固含量是按体积计算的

猜你喜欢
相关文献